Flame Retardant Instrumentation Cable

Annealed copper conductor core twisted multi pair plastic insulation and sheath flame retardant instrumentation cable .

Send InquiryChat Now
Product Details

Flame Retardant Instrumentation Cable 

Annealed copper conductor core twisted multi pair plastic insulation and sheath flame retardant instrumentation cable .


1.Technical Parameter

a.Conductor , solid /stranded/flexible copper

b.Nominal cross section ,0.5mm2,0.75mm2,1.0m2, 1.5mm2

c.Core No. Multi Cores

d.Insulation material, PVC /XLPE/PE

e.Shielded,No

f. Armoured,No

g.Sheath material,PVC /XLPE/PE

h.Flame retardant rate, Class A ,Class B, Class C

i.Making,on request

j.Rated voltage,450/750V

k.HS code,8544422100

l.Executive standard, Q/321084KKA01-1996 or BS5308-86

 

2.Changcheng  Advantages for Instrumentation Cable

Changcheng is one professional manufacturer who concentrate on instrumentation    cables for nearly 30 years. We can supply instrumentation cables with low minimum production quantities and competitive lead times. Chanchange can assist in the design of the perfect instrumentation  cable for the intended application.

 

3.Customized Instrumentation Cable

Instrumentation cables comply to BS5308 standard and can be customized to produce to meet various requirements of overseas clients .For example, the diameter of insulation, core identification ,insulation material and rated voltage  can be designed by you .

 

4.Flame retardant instrumentation cable

The flame retardant cable is mainly featured in low liability of fire or that second combustion is only limited to a certain range, meets the IEC60332 combustion testing requirements, and is applicable to the places with flame retardant requirement.

 

5.Flame retardant cable Main features

(1). Ordinary flame retardant cable
For Class A and Class B fire tests, the fire time is 40 minutes, and for Class C and Class D fire tests, the fire time is 20 minutes, and the charring height does not exceed 2.5 m.
(2). Low-halogen low-smoke flame retardant cable
Halogen acid gas emission <100 mg/g, smoke density (transmittance) > 30%, from the group burning test, it meets the requirements of Class C flame retardancy.
(3). Low smoke zerohalogen (LSZH) flame retardant cable:
Halogen acid gas all-emission 0 mg/g, pH value ≥ 4.3, conductivity ≤ 10 us/mm, toxicity index ≤ 5. From the group burning test, it at least meets the requirements of Class C flame retardancy, smoke density (transmittance) ≥
60%.
(4). Oxygen barrier cable (highly-flame retardant cable)
From the group burning test, it meets and exceeds the requirements of Class A flame retardancy, and the smoke density (transmittance) is equal to or close to national standard GB/T17651-2008 and international standard IEC61034 low smoke standard.
It is especially suitable for 6 KV-35 KV medium-voltage cable frame retardancy, has not only flame retardancy up to Class A, but also has certain refractory characteristics (i.e. can still keep 2.4 Uo insulation standard after burning for 20 min).
Notes: Users can select category and class of flame retardant cable according to laying places.

Hot Tags: flame retardant instrumentation cable, China, suppliers, manufacturers, factory, wholesale, customized, cheap, low price